Expert service · Greenhouse gas accounting · GHG

Your bank asks for scope 1, 2 and 3 emissions.

Your customers may ask for the same figures in their questionnaires or through CDP's global environmental disclosure system. A company carbon footprint is a greenhouse gas inventory for one year, in tonnes of CO₂ equivalent, or t CO₂e. Our team prepares it to the GHG Protocol Corporate Standard, the rules for a company-wide inventory.

  • Prepared to the GHG Protocol Corporate Standard
  • Checker independent of EuFSI, if asked
  • Based in Enschede, the Netherlands

Records and factors

Every scope figure comes from one inventory

t CO₂eExample

Scope 1Sites and vehicles you own or control
1,240t CO₂e
Scope 2Electricity and heat you buy
860Location-based 540Market-based
Scope 3The rest of your value chain
3,900t CO₂e

Each quantity is multiplied by its emission factor, the emissions per unit.

Your records sit inside the boundary of your companies and sites. Fuel and gas invoices in litres and m³ are multiplied by an emission factor for scope 1. Electricity invoices in kWh are multiplied by the grid average for the location-based scope 2 figure. If your electricity market allows, they are also multiplied by your contract's factor for the market-based figure. Spend in the purchase ledger is multiplied by a spend-based factor for an estimate of scope 3. A supplier's reply passed on by you can replace part of the scope 3 estimate. All three scopes sit in one greenhouse gas inventory, prepared to the GHG Protocol Corporate Standard. The figures shown are an example.

Your companies and sites

Greenhouse gas inventory

t CO₂eExample

  1. Fuel and gas invoiceslitres and m³

    multiplied by emission factor

    Scope 11,240

  2. Electricity invoiceskWh

    multiplied by grid average

    Scope 2Location-based860

    multiplied by your contract

    Market-basedIf your electricity market allows540

  3. Purchase ledgerspend

    multiplied by spend-based factor

    Scope 3Estimate3,900

    Supplier replyPassed on by you

GHG Protocol Corporate Standard

The request you received sets how far scope 3 goes.

A supplier's reply that arrives before the report is final can replace the estimate.

What you receive

The GHG Protocol sets the report's contents

An example greenhouse gas inventory report, drawn open on its cover and contents page.

Contents

  • Boundary of companies and sites
  • Reporting year and base year
  • Scope 1 and 2 in t CO₂e
  • Scope 3 by category if included
  • Seven greenhouse gases
  • Emission factors with source and version
  • Exclusions with reasons

Outside the totals

  • CO₂ from burning biomass
  • Carbon credits

Data we ask for once

Your teams hold the records we ask for

We ask for this once. Our team reuses it if you order other outputs.

We also ask for freight, travel and waste invoices.

EuFSI

One data request

  • Energy and fuelFinance, site manager
  • Supplier repliesPurchasing
  • Sites and productionSite manager
  • Purchase ledger by supplierFinance, purchasing
  • Electricity contractsFinance, purchasing
  • Refrigerant service logSite manager

Only the EuFSI team works on your files. They are used only for the work you order.

How it runs

Five steps from the call to the report

  1. Call

    You and our team

    The request and its due date

  2. Written quote

    Our team

    The companies and sites, the year and how far scope 3 goes

  3. Data request

    Our team, then you

    From your records and your suppliers' replies

  4. Inventory

    Our team

    Each scope, with its sources and methods stated

  5. Report, and any check

    Our teamIndependent checker

    A checker independent of EuFSI, if your bank or customer asks

The timeline depends on complete energy and purchase records, your suppliers' replies and the checker's calendar if a check applies.

Your sites can be inside or outside the EU.

Questions

Do we receive a certificate?

You receive a report prepared to the GHG Protocol Corporate Standard. The GHG Protocol requires no check. If a customer or bank asks for one, a checker independent of EuFSI examines the inventory.

A verification body follows ISO 14064-3, the standard for verifying greenhouse gas statements. An assurance provider follows ISSA 5000 or ISAE 3410, two international assurance standards. Our team gives the checker the calculations and answers its questions until the check is complete.

For the CO2-Prestatieladder, a Dutch certification scheme for CO₂ reduction, a recognised certifying body audits the company each year. The Ladder's certificate needs more than an inventory and is valid for three years.

Do we have to include scope 3?

Not under the GHG Protocol Corporate Standard. It requires scope 1 and 2 and leaves scope 3 optional.

Your customer may still ask for it, in its own questionnaire or through CDP. A customer committed to having its suppliers set science-based targets may ask too. These are emission targets in line with the Paris Agreement.

The Dutch CO2-Prestatieladder asks for scope 3 from step 2 of version 4.0. If the request you received asks for scope 3, the written quote says how far it goes.

What if a figure is missing, or a supplier does not reply?

If a figure is missing, our team can estimate it from part-year invoices, floor area or a similar site. The report states the method and marks each estimate.

Scope 3 can start from what you spent, before your suppliers reply. Anything left out is listed in the report with its reason.

Our electricity is green. Is our scope 2 zero?

Only in the market-based figure, if your contract or guarantees of origin meet the GHG Protocol's quality criteria. Guarantees of origin are certificates that show where your electricity comes from.

The location-based figure, from the grid average, is always reported as well. A VSME report, the EU's voluntary sustainability report, asks for the location-based figure.

How long is the inventory valid?

The GHG Protocol sets no expiry date. An inventory covers one reporting year, either a calendar year or your financial year. The customer, bank or scheme names the year it wants.

The base year is the year later inventories are compared with.

Can we call ourselves climate neutral?

Not on the basis of the inventory. An inventory counts emissions and does not cancel them.

Carbon credits are never deducted from the totals. Any you hold can be listed separately.

EU consumer law bans claims to consumers that a product's climate effect is neutral, reduced or positive because of offsetting. It also bans generic environmental claims, such as “eco-friendly”, unless the trader can show recognised excellent environmental performance.

A quote starts from the request you received

Tell us who asked, for which year and by when.

LCADPPEPDGHGCSRD · VSMECBAM